The Theta 30P compact programmable Transducers are available with LCD display and are completely on-site configurable.

Features

  • True RMS measurement
  • On-site configurable as: Active / Reactive / Apparent / Phase Angle / Power Facto
  • On-site programmable inputs
  • On-site selectable output; DC Current or DC Voltage
  • Seven segment LCD display
Theta 30P compact programmable Transducers

Theta 50 is used to electrically isolate input, outputs & power supply. It fills all requirements & regulations concerning electromagnetic compatibility (EMC) & safety (IEC 61326-1 & IEC 61010-1-2010)

Features

• Accuracy class 0.2 as per International Standard IEC/EN 60 688
• Output Response Time < 250 ms
• Fast and easy installation on DIN RAIL or onto a wall or in panel using optional screw hole bracket.

Theta 10A/10V transducer converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.

Features

• Accuracy class 0.2 as per International Standard IEC/EN 60688
• Output Response Time < 250 ms
• Fast and easy installation on DIN RAIL or onto a wall or in panel using optional screw hole bracket.

Theta 10A10V Transducer

The Theta 20A/20V compact programmable Transducers are available with LCD display and are completely on-site configurable.

Features

  • True RMS measurement
  • On-site programmable inputs
  • On-site selectable output; DC Current or DC Voltage
  • Single or Dual output
  • Seven segment LCD display

P19 Temperature and Humidity Transducer.

Features

• Built-in temperature and humidity sensor
• Calculation of selected physical quantities (dew-point temperature, absolute humidity)
• Storage of measured and calculated maximum and minimum values
• Interface RS-485 galvanically isolated (Modbus protocol)

Transmitter Theta 60R available in 1 channel version, in housing S17 clipped on to a top – hat rail and 2 channel version, in housing S17 hole mounting brackets pulled out. The transmitter Theta R converts the input variable-a signal from a resistance thermometer Pt 100- to a temperature linear output signal.

Features

• Measuring ranges configurable with DIP switch and potentiometer
• Red LED’s indicator: an open or short-circuit
• Electric isolation between input & output 2.3kV and power supply to all other circuits 3.7kV – fulfils EN 61 010
• Provision for either snapping the transmitter onto top-hat rails or securing it with screws to a wall or panel
• Housing only 17.5mm wide (size S17) / low space requirement

Theta 60 R - Transmitter

P30U transducer is designed to convert temperature, resistance, standard voltage and current signals into a standard DC voltage or DC current signal.

The output signal is galvanically isolated from the input signal and the power supply.
P30U has programmable measurement and additional functions.
Programming parameters can be realized with the use of buttons, via RS-485 interface and free e-con software or Ethernet or any web browsers via Ethernet interface.The device fulfills the requirements of III installation’s category for the products designed to industrial application.
 
Features:
  • Input: programmable.
  • Output: programmable
  • display: LCD 2 x 8 characters with backlit.
  • Indication of exceeding the alarm values.
  • Indication of exceeding the alarm values.
  • programming the measurement averaging time.
P30 U - Transmitter

P43 Three Phase Programmable Transducer.

Features:

  • Measurement and conversion of power network parameters in 4-wire balanced or unbalanced systems.
  • Tetra quadrant energy measurement (Ep+, Ep-, EQL, EQc).
  • Programmable current and voltage transformer ratios.
  • Detection and signalling of incorrect phase sequence.

The P17 transducer is destined to convert the signal from temperature, resistance or voltage sensors into a 4…20 mA current signal.

Features:

  • Can be treated as an active load forcing a current proportional to input signal changes from the supplying circuit.
  • Input: Input:Voltage 0…10V, 0…60mV.
  • Output: 4…20mA.
  • Supplied from a current loop.
  • Overall dimensions: 6.2 × 99 × 77mm.
P17 Temperature Transducer
Measuring transducer P21Z type is destined to a continuous conversion of A.C. current or A.C. voltage without the constant component or frequency into a standard d.c. current or d.c. voltage signal or digital signal.
The transducer output signal is galvanically insulated from the input signal and the supply.The device fulfils the requirements of CAT III installation’s category for the products designed to industrial application.
 
Features:
  • input:100, 250, 400 V A.C.1 A, 5 A a.c.  20…50 Hz.
  • output:0/4…20mA, 0…10 V RS-485 with Mod bus protocol.
  • Measurement of averaging time.
  • Value of output signal when limit value are exceeded.
  • external dimensions: 22,5 x 120 x 100 mm.

P 30P Single Phase power network Transducer. 

Features:

  • Measurement of 1-phase power network parameters.
  • Conversion of measured value in an output signal on the base of the individual characteristics 1 or 2
  • Alarm relays with NO contact operating in 6 modes.
  • Recording of input signals in internal memory, on SD/SDHC card (option)
  • Protocol: Modbus TCP/IP, HTTP, FTP.

Programmable transducer P30O type is destined to convert of number of pulses, number of working hours, frequency, period and rotational speed into a digital or standard current or voltage signal.

Features:

  • 2 universal pulse inputs.
  • Mathematical functions for each input.
  • Data recording.
  • Firmware upgradeable by the user.
  • External dimensions: 45 x 120 x 100mm

THETA PI 102: Programmable Dual output DC Isolator

The purpose of the THETA PI-102 is to electrically isolate input, outputs and power supply. The isolator fulills all requirements and regulation concerning electromagnetic compatibility EMC and safety (IEC61326-1 and IEC 61010-1:2010).

The device has one input and provides two independent outputs in an extremely small space.

Features:

  • All input signal range and output signal range are user programmable.
  • Electric isolation between input, outputs and power supply.
  • Prevents false measurement due to spurious potentials.
  • Processes live zero signals, provision for signal conversion.
  • Electrical insulation between power supply versus all other circuits.
  • 3.0 kV, and between input and outputs -2.3 kV.
×